OEM-Compliant — Full SE Documentation Provided

MRI RF Shielding
Engineered to Spec

From site planning guide to SE certification — we speak your language.

Copper Faraday cages designed to each scanner manufacturer's RF attenuation requirements. We provide full technical documentation: SE test reports, waveguide specifications, and RF penetration schematics — everything required for compliance sign-off.

300+ Installations Worldwide
100% SE Compliance Guaranteed
Operational in Days

Proud to
Partner With

Esaote Canon Medical Philips Siemens Healthineers GE HealthCare Hitachi Fujifilm
0+ Years of Experience
0+ MRI Rooms Shielded
0% SE Compliance Rate
0+ Countries Served

The Technical Compliance Challenge

Every MRI scanner comes with a site planning guide specifying minimum shielding effectiveness. Meeting those specs — while managing RF penetrations, waveguides, quench pipes, and HVAC — requires engineering expertise most general contractors don't have.

A failed SE test means costly rework and schedule delays. Getting it right the first time requires a shielding partner with documented experience across all major OEMs.

Full Technical Documentation. First-Time Pass.

We design copper Faraday cages to meet or exceed manufacturer-specified attenuation levels for Siemens, Philips, GE, Canon, Hitachi, and Esaote. RF penetrations, waveguides, and filters are all engineered, specified, and supplied.

Every project concludes with a certified SE test report using calibrated signal generator and spectrum analyzer — the documentation you need for compliance approval and OEM warranty purposes.

Humanized MRI room with mood lighting and landscape wall decal
Room Concept

Room design that doesn't compromise the shield

Our room concept integrates mood lighting, window decals, and chromotherapy systems using only MRI-compatible materials — fully co-engineered with the Faraday cage structure. No compromises to RF integrity, no additional penetrations beyond what's specified.

Patient Comfort

Tailored environments reduce stress, improving scan compliance and diagnostic quality.

Mood Lighting

Multi-colour chromotherapy lighting systems programmable in sequences and intensities.

Window Decals

High-resolution MRI-compatible landscape prints — sky, sea, nature — fully customisable.

Perfectly Integrated

All elements are MRI-compatible and seamlessly integrated with the shielding structure.

View Technical Integration Details

Complete MRI Room Solutions

From Faraday cage engineering to patient-centered room design, we handle every detail.

RF & Magnetic Shielding

Custom-designed Faraday cages with copper and aluminum shielding solutions, engineered for your specific MRI system and facility requirements.

Room Concept & Design

Patient-first environments with mood lighting, window decals, and chromotherapy to reduce anxiety and claustrophobia during MRI scans.

SE Testing & Certification

Every installation undergoes rigorous Shielding Effectiveness testing to ensure 100% compliance with manufacturer specifications.

Worldwide Installation

Our own certified technicians install globally. Shipping of complete mounting kits to any location, operational in days.

Turnkey Project Management

End-to-end service from site survey and design through manufacturing, installation, testing, and ongoing maintenance support.

Veterinary MRI Systems

Specialized shielding solutions for veterinary diagnostic facilities, with the same precision and quality standards as medical-grade installations.

How It Works

Whether you already have an MRI or you're planning from scratch, we've got you covered.

1

Consultation

Tell us about your project — MRI model, room dimensions, timeline. We assess your needs and provide a tailored recommendation.

2

Design & Engineering

Custom shielding design matched to your MRI system specs and facility layout, with detailed technical drawings.

3

Manufacturing

Precision in-house manufacturing of your Faraday cage and shielding components, quality-controlled at every stage.

4

Installation & Testing

Our own technicians install on-site anywhere in the world, followed by rigorous SE testing to certify full compliance.

Already Have Your MRI?

We work around your existing system's specifications. Installation completes in days, with full SE testing and certification included.

Schedule Installation

Planning From Scratch?

We design your shielded room before the machine arrives, coordinating directly with the MRI manufacturer for a seamless setup.

Start Planning

Our Portfolio

Discover how our expertise, innovation, and commitment to excellence have consistently delivered outstanding results for our clients worldwide.

Request a Technical Review

Share your scanner model and OEM site planning guide — we'll review the specs and provide a detailed technical proposal with attenuation calculations.

OEM site planning guide compliance guaranteed
Certified SE test report — calibrated equipment
RF penetrations, waveguides & filters supplied
Technical response from certified engineers

No obligation — we'll get back to you within 24 hours.

Get the Shielding Spec Right the First Time

Full technical documentation, certified SE testing, and OEM compliance — on every project, worldwide.